Control macros 143
Pharma macro
The various machines used in the pharmaceutical industry, e.g. Agitators, mixers,
centrifuges, etc. are driven by motors which are controlled by drives. You can use the
Pharma macro to automatically configure the basic drive parameters required to
control these machines.The following settings are configured automatically with this
macro:
• Start, stop, and multiple constant speed selections
• Ramp time
• Motor control
• Relay output
• Analog output
The below figure explains how a drive is connected to a motor in a reactor.
To enable the Pharma macro, navigate to
•
Main menu
Connection macro
Pharma
or
•
Main menu
Complete parameter list
parameter
[19]
.
Reactant 2
Reactant 1
to vent
system
Stirrer
Coolant
Product
outlet
Motor
Drive