Chapter 4 OPERATION
12. "SYSTEM" mode
Chapter 4 OPERATION
4-233
Setting
Meaning
HOLD
Outputs are not
reset.
The DO/MO/LO/TO/SO port outputs are not reset even
when any of the followings are executed.
The outputs are not reset even:
■
When compile ended successfully in "PROGRAM"
mode.
■
When a program was compiled in "AUTO" mode and
the compile ended successfully.
■
When
(RESET) was executed in "AUTO" mode.
■
In "AUTO" mode, when the dedicated input signal
DI15 or SI15 (Program reset input) was turned on
while the program was stopped. (See "1.6 Dedicated
input signal description" in Chapter 6.)
■
When either of the following was initialized in
"SYSTEM>INIT" mode.
1. Program memory
(SYSTEM>INIT>MEMORY>PROGRAM)
2. All memories
(SYSTEM>INIT>MEMORY>ALL)
■
When the SWI command was executed by "DIRECT"
in "AUTO" mode.
■
When an online command @RESET, @INIT PGM,
@INIT MEM, @INIT ALL or @SWI was executed.
■
When the HALT or SWI statement was executed in the
program.
Содержание RCX240