12. "SYSTEM" mode
4. DO cond. on EMG /EMGCDO
This parameter sets whether or not to hold output of the DO/MO/LO/TO/SO ports when an
emergency stop signal is input to the controller. This is automatically set to "HOLD" when the
parameters are initialized.
1
Select "4. DO cond. on EMG " in "SYSTEM>PARAM>OTHERS" mode.
2
Press
(EDIT).
SYSTEM
>PARAM>OTHERS V10.01
1.Display language(JPN/ENG) ENGLISH
2.Data display length 6char
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Watch on STD.DIO DC24V VALID
RESET HOLD
Setting " DO cond. on EMG"
3
Press
(RESET) or
(HOLD) to enter the setting.
4
Press
to quit the edit mode.
c
CAUTION
This parameter is invalid if the sequence program starts up.