Chapter 3 INSTALLATION
Chapter 3 INSTALLATION
3-7
3. Connector names
Connector names, locations and functions are shown below.
RPB
MOTOR
XM
YM
ZM
RM
PWR
SRV
SAFETY
RPB
COM
STD.DIO
ROB
I/O
ZR
OP.1
OP.3
OP.2
OP.4
RGEN
ACIN
N
P
N1
L1
L
N
SEL
BATT
ZR
XY
BATT
ROB
XY
I/O
PIN
13
−
14
EXT.E-STOP
ERR
RCX240
t
COM
o
RPB SEL
e
SAFETY
q
XM
q
YM
q
ZM
q
RM
u
OP.1
r
RPB
u
OP.3
u
OP.2
u
OP.4
!0
RGEN
!1
ACIN
!2
FG
w
ROB I/O XY
i
BATT XY
i
BATT ZR
w
ROB I/O ZR
y
STD.DIO
Connector names
Connector name
Function
q
XM/YM/ZM/RM
Connectors for servomotor drive
w
ROB I/O [XY/ZR]
Connectors for servomotor feedback and sensor signals
e
SAFETY
Input/output connector for safety function such as
emergency stop
r
RPB
Connector for RPB
t
COM
RS-232C interface connector.
y
STD.DIO
Connector for dedicated input/output and standard
general-purpose input/output
u
OP. 1, 2, 3, 4
Connectors attached to optional expansion I/O boards
i
BATT [XY/ZR]
Battery connector for absolute backup
o
RPB SEL
RPB selector switch contact
!0
REGN [P/ /N]
Connector for regenerative unit
!1
AC IN [L/N/L1/N1]
Terminal block for power cable. Use ring-tongue terminals
to make connections.
!2
FG
Ground terminal ( ). Provide Class D grounding (100
ohms or less).
w
WARNING
TO PREVENT ELECTRICAL SHOCkS, NEVER TOUCH THE RGEN AND AC IN TERMINALS
WHEN POWER IS SUPPLIED TO THE ROBOT CONTROLLER.
3. Connector names
Содержание RCX240
Страница 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 18: ......
Страница 34: ......
Страница 78: ......
Страница 402: ......
Страница 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Страница 450: ......
Страница 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Страница 482: ......
Страница 494: ......
Страница 506: ......
Страница 512: ......
Страница 522: ......
Страница 611: ...INDEX ...
Страница 612: ......
Страница 617: ......
Страница 619: ......