Chapter 4 OPERATION
12. "SYSTEM" mode
Chapter 4 OPERATION
4-219
5. Watch on STD.DIO DC24V /STDWCH
This parameter sets whether or not to enable the dedicated interlock signal input when there
is no STD.DIO DC24V power being supplied. This is automatically enabled (valid) when the
parameters are initialized.
n
NOTE
When DC 24V is supplied to the STD. DIO and SAFETY connector, this parameter is
enabled (valid) regardless of the setting.
1
Select "5. Watch on STD.DIO DC24V" in "SYSTEM>PARAM>OTHERS"
mode.
2
Press
(EDIT).
SYSTEM
>PARAM>OTHERS V10.01
1.Display language(JPN/ENG) ENGLISH
2.Data display length 6char
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Watch on STD.DIO DC24V VALID
INVALID VALID
Setting the "Watch on STD.DIO DC24V"
c
CAUTION
• Make sure this setting is enabled (valid) when the robot will be in normal
operation.
• the interlock signal sends a stop command such as for stopping robot operation.
If the interlock setting is off (disabled) use caution during robot operation.
3
Press
(INVALID) or
(VALID) to enter the setting.
4
Press
to quit the edit mode.
Содержание RCX240
Страница 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 18: ......
Страница 34: ......
Страница 78: ......
Страница 402: ......
Страница 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Страница 450: ......
Страница 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Страница 482: ......
Страница 494: ......
Страница 506: ......
Страница 512: ......
Страница 522: ......
Страница 611: ...INDEX ...
Страница 612: ......
Страница 617: ......
Страница 619: ......