A-72
TROUBLESHOOTING
A
TROUBLESHOOTING
A-73
[22] Major hardware errors
22.40 : PCMCIA interface overtime
Code
: &H1628
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
PCMCIA interface.
1. Replace the PCMCIA interface driver.
2. Replace the controller.
22.41 : OPT.1 interface overtime
Code
: &H1629
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 1.
1. Replace the option board connected
to option slot 1.
2. Replace the controller.
22.42 : OPT.2 interface overtime
Code
: &H162A
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 2.
1. Replace the option board connected
to option slot 2.
2. Replace the controller.
22.43 : OPT.3 interface overtime
Code
: &H162B
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 3.
1. Replace the option board connected
to option slot 3.
2. Replace the controller.
22.44 : OPT.4 interface overtime
Code
: &H162C
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 4.
1. Replace the option board connected
to option slot 4.
2. Replace the controller.
Содержание RCX240
Страница 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 18: ......
Страница 34: ......
Страница 78: ......
Страница 402: ......
Страница 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Страница 450: ......
Страница 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Страница 482: ......
Страница 494: ......
Страница 506: ......
Страница 512: ......
Страница 522: ......
Страница 611: ...INDEX ...
Страница 612: ......
Страница 617: ......
Страница 619: ......