RS_SDIO controller
RM0082
728/844
Doc ID 018672 Rev 1
32.7.27 MAXCURR2
register
The MAXCURR2 bit assignments are given in
32.7.28 ACMD12FEERSTS
register
The Force Event Register is not a physically implemented register. Rather, it is an address
at which the Auto CMD12 Error Status Register can be written.
Writing logic ‘1’: set each bit of the Auto CMD12 Error Status Register
Writing logic ‘0’: no effect.
The ACMD12FEERSTS bit assignments are given in
.
Table 650.
MAXCURR2 register bit assignments
Bit
Name
Reset
value
Type
Description
[31:00]
-
-
Rsvd
Reserved
Table 651.
Maximum current value definition
Register value (decimal)
Current value
0
Get information through another method
1
4 mA
2
8 mA
3
12 mA
---
---
---
---
255
1020 mA
Table 652.
ACMD12FEERSTS register bit assignments
Bit
Name
Reset
value
Type
Description
[15:08]
-
-
Rsvd
Reserved
[07]
FECMDNI
1’h0
WO
Force Event for command not issued by Auto
CMD12 Error
1’b1 - Interrupt is generated
1’b0 - no interrupt
[06:05]
-
-
Rsvd
Reserved
[04]
FEACMDIDX
1’h0
WO
Force Event for Auto CMD12 Index Error
1’b1 - Interrupt is generated
1’b0 - no interrupt
[03]
FEACMDEB
1’h0
WO
Force Event for Auto CMD12 End bit Error.
1’b1 - Interrupt is generated
1’b0 - no interrupt