7-64
Rev.2.00
7
5. Timing Chart
Supplement
Alarm
When an Alarm has been Cleared (At Servo-ON Command)
Dynamic brake
Servo-ON status
output
*
1
Alarm-clear instruction
(
RTEX command/USB
)
Approx. 2 ms
Approx. 25 ms
16 ms or longer
ON
ON
OFF
OFF
Engaged
Released
Motor energization
Brake release output
(
BRK-OFF
)
Servo-Ready output
(
S-RDY
/RTEX status
)
Servo-Alarm outpu
(
ALM
/RTEX status
)
Approx. 60 ms
Energized
Not-energized
Output Tr OFF
(
Brake engage
)
Output Tr ON
(
(Brake release
)
Output Tr OFF
(
Not ready
)
Output Tr ON
(
Ready
)
Output Tr OFF
(
Alarm
)
Output Tr ON
(
Not alarm
)
No input entry
Input enabled
Position/Speed/
Torque instruction
(
RTEX command
)
100 ms or longer
Approx. 4 ms
*1 Note that the servo-on status output signal is to let you know of the receipt of servo-on
command and is not an output to let you know that command input is possible.
Caution