5.
Wiring of the Main Circuit
A to B-frame (100 V/200 V Type)
Wiring Sequence
1) Wire connector (XA and XB). (The method of connection refer to P.2-39
)
2) Connect the wired connector to the driver.
Fully insert the connector to the bottom until it is locked.
• Wiring should be performed by a specialist or an authorized personnel.
• Do not turn on the power until the wiring is completed.
• Never touch the power connector (XA and XB) to which high voltage is applied.
There is a risk of electric shock.
Tips on Wiring
Motor
Varistor
DC
24 V
MCCB
Power
supply
NF
MC
U
V
W
E
L
Fuse (125 V 10 A)
• Check the name plate of the driver for power
specifications.
• Provide a residual current device. The residual
current device to be the one designed for "Inverter"
and is equipped with countermeasures for harmonics.
• Provide a circuit breaker (MCCB).
• Make sure to provide a noise filter.
• Provide coil surge suppression units to the coil of the
Magnetic Contactor recommended by manufacturer.
Do not start/stop the motor with this Magnetic
Contactor.
• Provide an AC Reactor.
•
Connect L1 and L1C, and L3 and L2C at single
phase use (100 V and 200 V), and do not use L2.
• Match the colors of the motor lead wires to those of the
corresponding motor output terminals (U,V,W).
•
Do not connect anything to N.
•
Avoid shorting and grounding. Do not connect the
main power.
•
Earth-ground this.
• To prevent electric shock, be sure to connect the ground
terminal ( ) of the driver, and the ground terminal
(ground plate) of the control panel.
• The ground terminal ( ) must not be shared with
other equipment.
Two ground terminals are provided.
•
Do not connect the earth cable to other inserting
slot, nor make them touch.
• Compose a duplex Brake Control Circuit so that the
brake can also be activated by an external immediate
stop signal.
• The holding brake has no polarities.
• For the holding brake power supply capacity and how to
use the brake, refer to “Built-in Holding Brake” on
P.2-65.
• Provide a varistor.
Connect a 10 A fuse in series with the varistor.
Ground resistance: 100 Ω max.
For applicable wire, refer to P.2-18.
L1C
L3
L2
L1
L2C
P
N
B
U
V
W
XA
XB
2
3
4
5
1
2
3
4
5
6
1
DC power supply
for brake
Red
Black
Green or
Green/yellow
White
RCD
External regenerative
resistor
*
These colors
are used for
optional cable.
Note
Related page
The wiring indicated with the broken line shall be provided only when required.
• P.2-40 “Specifications of Motor Connector” • P.2-39 “Wiring method to Driver Connector”
• P.7-91 “Connector Kit XA” • P.7-92 “Connector Kit XB” • P.7-104 “External Regenerative Resistor”