Error code No.
Protective
function
Causes
Measures
Main Sub
6-12
1.When in Trouble
Detail of Error Code
Rev.2.00
33
0
*
Input
duplicated
allocation error
1 protection
Input signals (SI1, SI2, SI3, SI4) are
assigned with two functions
・
Allocate correct function to each connector
pin.
1
*
IInput
duplicated
allocation error
2 protection
Input signals (SI5, SI6, SI7, SI8) are
assigned with two functions.
2
*
IInput
function
number error
1 protection
Input signals (SI1, SI2, SI3, SI4) are
assigned with undefined number. Or,
logical setup is not correct.
3
*
Input
function
number error
2 protection
Input signals (SI5, SI6, SI7, SI8) are
assigned with undefined number. Or,
logical setup is not correct..
4
*
Output
function
number error
1 protection
Output signals (SO1) are assigned with
undefined number.
5
*
Output
function
number error
2 protection
Output signals (SO2,SO3) are assigned
with undefined number.
8
*
Latch input
allocation
error
protection
Error has occurred during function
assignment of latch correction pins
(SI5, SI6, and SI7).
• EXT1 must be allocated to SI5. EXT2
to SI6 and EXT3 to SI7: but these are
assigned to other pins.
• HOME is allocated to SI6 or SI7; POT
is allocated to SI5 or SI7; NOT is
allocated to SI5 or SI6.
• Function not allocated to one or more
control modes.
Note
• When protective function marked with
*
in the protective function table is activated, it cannot
be disabled by the alarm clear input (USB conmmunication(PANATERM) or RTEX alarm
clear commond). To return to the normal operation, turn off power, and then turn on power
again,or use soft reset commond by RTEX conmmunication.