A parameter is designated as follows:
Pr0.00
No.
Class
・
For
“ Attribute ”,refer to P.3-38
“ Details of Attribute ”.
・
P.2-47
〜
“ Wiring to the Connector, X4 ”
Pr5.57
Slow stop S-shape acceleration and
deceleration setting
Range
Unit
Attribute
Default
Related
control code
0 to 10000
ms
B
0
P S T
Sets the S-shape time for immediate stop deceleration stop deceleration processing.
This parameter will become valid when Pr6.10 “Function enhancement setting” bit 15 = 1
.
Pr5.66
Deterioration diagnosis convergence
judgment time
Range
Unit
Attribute
Default
Related
control code
0 to 10000
0.1 s
A
0
P S T
Sets time for deemed convergence of real-time auto tuning load characteristics estimate
when deterioration diagnosis warning function is valid (Pr6.97 bit 1 = 1).
Pr5.67
Deterioration diagnosis inertia ratio
uppe limit
Range
Unit
Attribute
Default
Related
control code
0 to 10000
%
A
0
P S T
Sets the upper limit values for inertia ratio estimate in deterioration diagnosis judgment of
load characteristics estimate after completion of convergence, when deterioration diagnosis
warning is valid (Pr6.97 bit 1 = 1).
Pr5.68
Deterioration diagnosis inertia ratio
lower limit
Range
Unit
Attribute
Default
Related
control code
0 to 10000
%
A
0
P S T
Sets the lower limit values for inertia ratio estimate in deterioration diagnosis judgment of
load characteristics estimate after completion of convergence, when deterioration diagnosis
warning is valid (Pr6.97 bit 1 = 1).
Pr5.69
Deterioration diagnosis unbalanced
load upper limit
Range
Unit
Attribute
Default
Related
control code
-1000 to 1000
0.1 %
A
0
P S T
Sets the upper limit values for unbalanced load estimate in deterioration diagnosis judgment
of load characteristics estimate after completion of convergence, when deterioration
diagnosis warning is valid (Pr6.97 bit 1 = 1).
Pr5.70
Deterioration diagnosis unbalanced
load lower limit
Range
Unit
Attribute
Default
Related
control code
-1000 to 1000
0.1 %
A
0
P S T
Sets the lower limit values for unbalanced load estimate in deterioration diagnosis judgment
of load characteristics estimate after completion of convergence, when deterioration
diagnosis warning is valid (Pr6.97 bit 1 = 1).
Pr5.71
Deterioration diagnosis dynamic
friction upper limit
Range
Unit
Attribute
Default
Related
control code
-1000 to 1000
0.1 %
A
0
P S T
Sets the upper limit values for dynamic friction estimate in deterioration diagnosis judgment
of load characteristics estimate after completion of convergence, when deterioration
diagnosis warning is valid (Pr6.97 bit 1 = 1).