Operation and Display of the Front Panel
Node address setting rotary switch
Setting range: 0 to 31
Analog monitor connector (X7)
2-digit 7-segment LED for display
Network States LED
LINK LED
COM LED
For details of the connector X7, refer to P.2-64
“Wiring to the
Connector, X7
”
Node Address
• Set the node address (MAC-ID) in a decimal number: high order digit on MSD rotary switch
and low order on LSD switch.
Example: When MAC-ID is 13, MSD = 1, LSD = 3.
•
The setting for rotary switch
to be using a flat-blade screwdriver (Edge width: less than 2.6
mm, Thickness: less than 0.6 mm).
• Node address (MAC-ID) set with the rotary switch will be loaded once when the control
power is turned on. Therefore, a change made after the power up will not be reflected to the
control but will become active upon the next power up.
• To avoid unnecessary trouble, after the power supply is turned on ,do not change the val
-
ues of rotary switch.
• Setup range of the node address (MAC-ID) is 0 to 31. If the setup value exceeds 31, Err
82.0 “COM invalid node-address protection” will be occurred.
2
Preparation
13.
How to Use the Front Panel
Setup
Note