![Panasonic MINAS A6N Series Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/panasonic/minas-a6n-series/minas-a6n-series_operating-instructions-manual_278150103.webp)
2-73
Rev.2.00
1
Before Using the Products
2
Preparation
3
Setup
4
Trial Run
5
Adjustment
6
When in T
rouble
7
Supplement
Network Status LED
Status indication and description of RTEX network status LED (COM/LINK).
LINK LED
COM LED
■
LINK LED
Display
status
Description
Not lit
Not connected
(Transmission node is not powered on, or cable is broken etc.)
Lit green
Connected normally
(TX of transmission node and RX of local node are correctly connected
electrically.)
■
COM LED
Display
status
Description
Not lit
Initial
Blinking
green
Ring Config
Lit green
Network established
Blinking red
RTEX communication-related clearable alarm occurs.
Lit red
RTEX communication-related unclearable alarm occurs.
• While an alarm (e.g. Err.16.0) other than RTEX communication-related occurs, if an alarm
relating to RTEX communication occurs, the COM LED blinks red or lights up red according
to the above.
However, in this case, be aware that the 7-segment LED indicates the previous alarm, which
is not relating to RTEX communication.
• The LINK LED lights up momentarily irrespective of cable connection when the power is
turned on or a reset command is issued. This occurs due to internal initialization of a servo
driver, not due to an error.
• The state of the bit 4 of Pr.7.23 “RTEX function enhancement setup 2” can change the
condition for turning on COM LED.
•P.3-104 “Details of Parameter”
•P.6-5 “Details of Error Code”