5-58
Rev.2.00
5
5. Manual Gain Tuning (Application)
Adjustment
Quadrant Projection Suppression Function
Outline
Control configuration can be switched to suppress quadrant projection occurring during
arc interpolation of 2 or more axes. To be used in conjunction with load fluctuation sup
-
pression function.
Applicable range
This function can be applicable only when the following conditions are satisfied.
Conditions under which the Hybrid vibration damping function is activated
Control mode
• Should be position control mode
Others
• Should be in servo-on condition
• Elements other than control parameters, such as prohibition of deviation
counter clear command input and torque limit, etc. are set appropriately,
in a state where there are no obstructions in normal motor revolutions.
Caution
There are cases where effects cannot be observed under the following conditions.
Conditions which obstruct disturbance observer action
Load
• When rigidity is low (anti-resonance point exists in the low frequency
range of 10 Hz or lower).
• When non-linearity of load is strong from existence of backlash, etc.
• When action patterns are changed.
Related Parameter
Class No.
Title
Function
5
45
Quadrant projection
positive direction
compensation amount
Sets amount of compensation to be added to torque command
when the position command is in positive direction and quadrant
projection compensation function is enabled.
5
46
Quadrant projection
negative direction
compensation amount
Sets amount of compensation to be added to torque command
when the position command is in negative direction and quadrant
projection compensation function is enabled.
5
47
Quadrant projection
compensation delay
time
Sets the length of delay time for switching of amount of
compensation after position command has been reversed, when
quadrant projection compensation function is enabled.
5
48
Quadrant projection
compensation filter
setting L
Sets time constant for low-pass filter on the amount of
compensation on torque command when quadrant projection
compensation function is enabled.
5
49
Quadrant projection
compensation filter
setting H
Sets time constant for high-pass filter on the amount of
compensation on torque command when quadrant projection
compensation function is enabled.