A parameter is designated as follows:
Pr0.00
No.
Class
・
For
“ Attribute ”,refer to P.3-38
“ Details of Attribute ”.
・
P.2-47
〜
“ Wiring to the Connector, X4 ”
4. Details of Parameter
[Class 6] Special Setting
10 to 9
Gain switching
setup
Select the gain switching related parameter to be used when the real
time auto tuning is enabled.
Setup value
Function
[0]
Use the current setup.
1
Disable gain switching.
2
Enable gain switching.
This parameter should be setup bit by bit. To prevent setting error, use of the setup support
software is recommended when editing parameter.
Do not change this parameter while the motor is running. Updated parameters will be
effective when the motor stops after the result of load characteristics measurement is
confirmed.
<Setup procedure of bitwise parameter>
When setting parameter to a value other than 0, calculate the setup value of Pr6.32 in the
following procedure.
1) Identify the LSB of the setup.
Example: LSB of the torque compensation function is 4.
2) Multiply the setup value by power of 2 (LSB).
Example: To set the torque compensation function to friction compensation (middle):
2
4
× 4 = 64.
3) Perform steps 1) and 2) for every setups, sum up the values which are to be Pr6.32 setup value.
Example: Load characteristics measurement = enable, inertia ratio update = enable,
torque compensation = friction compensation (middle), stiffness setup = enable,
fixed parameter = set to a fixed value, gain switching setup = enable, then,
2
0
× 1 + 2
2
× 1 + 2
4
× 4 +2
7
× 1 + 2
8
× 1 + 2
9
× 2 = 1477
P.5-4
“ Real-Time Auto-Gain Turing ”
Pr6.34
For manufacturer’s use
Range
Unit
Attribute
Default
Related
control code
—
—
—
0
Please fixed to 0.
Pr6.35
For manufacturer’s use
Range
Unit
Attribute
Default
Related
control code
—
—
—
10
Please fixed to 10.
Pr6.36
Dynamic brake operation input
Range
Unit
Attribute
Default
Related
control code
0 to 1
—
R
0
P S T
Sets between enabling and disabling dynamic brake (DB) operation input by I/O.
Note) This function is available only when the main power is turned off.
0: Disabled 1: Enabled