3.Setup and List of Parameters
List of Parameters
Parametr No.
Title
Range
Default
Unit
Attribute
Related control
mode
Detail
page
Class
No.
A,B
type
C
type
D,E,F
type
P
S
T
4
44
Position comparison output pulse
width setting
0 to 32767
0
0.1 ms
R
○
○
○
3-75
4
45
Position comparison output polarity
selection
0 to 7
0
-
R
○
○
○
4
47
Pluse
output selection
0 to 1
0
-
R
○
○
○
4
48
Position comparison value 1
-2147483648 to
2147483647
0
command
unit
A
○
○
○
3-76
4
49
Position comparison value
2
-2147483648 to
2147483647
0
command
A
○
○
○
4
50
Position comparison value
3
-2147483648 to
2147483647
0
unit
A
○
○
○
4
51
Position comparison value
4
-2147483648 to
2147483647
0
command
unit
A
○
○
○
4
52
Position comparison value
5
-2147483648 to
2147483647
0
command
unit
A
○
○
○
4
53
Position comparison value
6
-2147483648 to
2147483647
0
command
unit
A
○
○
○
4
54
Position comparison value
7
-2147483648 to
2147483647
0
command
unit
A
○
○
○
4
55
Position comparison value
8
-2147483648 to
2147483647
0
command
unit
A
○
○
○
4
56
Position comparison output delay
compensation amount
-32768 to32767
0
0.1 us
R
○
○
○
4
57
Position comparison output
assignment setting
-2147483648 to
2147483647
0
-
R
○
○
○
3-77
【
Class 5
】
Enhancing Setting
Parametr No.
Title
Range
Default
Unit
Attribute
Related control
mode
Detail
page
Class
No.
A,B
type
C
type
D,E,F
type
P
S
T
5
03
Denominator of pulse output division
0 to 8388608
0
−
R
○
○
○
3-78
5
04
Over-travel inhibit input setup
0 to 2
1
−
C
○
○
○
3-79
5
05
Sequence at over-travel inhibit
0 to 2
0
−
C
○
○
○
3-80
5
06
Sequence at Servo-off
0 to 9
0
−
B
○
○
○
3-81
5
07
Sequence at main power off
0 to 9
0
−
B
○
○
○
3-82
5
08
LV trip selection at main power off
0 to 3
1
−
B
○
○
○
5
09
Detection time of main power off
70 to 2000
70
1 ms
C
○
○
○
※
“ Related control mode ”is thant P
:
Position control
、
S
:
Velocity control
、
T
:
Torque control.
※
For “ Attribute ”,refer to P.3-38 “ Details of Attribute ”.
Caution
Parameter with for “ Unit ”,set to parameter by setup support software “ PANATERM ”,please
pay attention to the setting of the number of units have changed.