7-segment LED
Control power up
Display of the Power supply on
All off
All on
[nA]
(
Node Address
)
(
approx. 0.6 s
)
Setup of RSW(e.g. MSD = 0, LSD = 3)
(Pn.7.01 The time specified by “Address display
time after powering-on setting”)
〈
Display of Node address
〉
Normal display (when Pr 7.00 [LED display] is 0.)
Alarm display
Warning display
[--]
Main power is ON and
RTEX communication
is synchronized.
Alternately blinks main and sub (with a
dot at the left) of the alarm code in
decimal number.
(e.g. overload)
Main power is OFF or
RTEX communication
is not synchronized.
Servo-ON
Servo-OFF
Alarm
occurred
Main code
Sub code
(with left dot)
Alarm
cleared
[--] + right side dot is lit.
[00] + right side dot is lit.
Displays warning code (hexadecimal) and
normal display alternately at a slow rate.
Right dot blinks when warning code
(Example of overload in servo-ON state)
is displayed.
Warning occurred
Warning code
(approx. 2 s)
Right dot blinks.
Normal display
(approx. 4 s)
Latched: remove the cause and
clear alarm
Unlatched: remove the cause
13. How to Use the Front Panel
Setup
•P.3-104 “Details of Parameter”