A parameter is designated as follows:
Pr0.00
No.
Class
・
For
“ Attribute ”,refer to P.3-38
“ Details of Attribute ”.
・
P.2-47
〜
“ Wiring to the Connector, X4 ”
Pr7.11
Positive side software limit value
Range
Unit
Attribute
Default
Related
control code
−1073741823
to 1073741823
Command
unit
A
500000
P
Pr7.12
Negative side software limit value
Range
Unit
Attribute
Default
Related
control code
−1073741823
to 1073741823
Command
unit
A
−500000
P
Note
Set up software limit on positive and negative direction. When the limit is exceeded, RTEX
communication status P_SOT/N_SOT will be turned ON (=1).
For operation, check to Materials of controllor.
・
Positive side software limit value must be larger than negative side software limit value.
・
When home return is not completed, P_SOT/N_SOT is not on.
Pr7.13
Absolute home position offset
Range
Unit
Attribute
Default
Related
control code
−1073741823
to 1073741823
Command
unit
C
0
P S T
Set up the offset value on encoder position when using absolute encoder and mechanical
coordinate system position.
Pr7.14
Main power off warning detection
time
Range
Unit
Attribute
Default
Related
control code
0 to 2000
1 ms
C
0
P S T
Caution
Specifies a time to wait until a main power off warning is detected when main power shut-off
continues.
RTEX communication status AC_OFF becomes 1 when main power off is detected.
setup value
Content
0
to
9
、
2000
Warning detection is disabled
10
to
1999
Unit is [1 ms]
Set this parameter so that Pr.7.14 becomes smaller than Pr.5.09 in order for the warning
detection is performed before shut-down detection. If the voltage between P and N of the
main power convertor is decreased to below a specified value before the warning is detected
because the setting value is long, the main power low voltage error (Err13.0) occurs before
the warning.
Pr7.15
Positioning adjacent range
Range
Unit
Attribute
Default
Related
control code
0 to 1073741823
Command
unit
A
10
P
The NEAR of the RTEX communication status becomes 1 when the difference between the
internal target position and command position is smaller than a specified value during profile
position control (PP).
4. Details of Parameter
[Class 7] Special Setting 2