Error descriptions
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
732
4.5
4.5
Error descriptions
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response
100
No Heap memory available
No Heap memory available
No response
101
Stack monitoring: stack consumption
has reached error threshold.
The stack consumption has reached error threshold. A safe opera-
tion is no longer possible. The additional info 1 of the error message
shows the task number in which the stack consumption is too large.
Pulse block
102
Error during indirect function access
Error during indirect function access
Pulse block
103
Real time load critical
The calculation time load of the real time is too high.
No response
114
Error division by zero
Division by zero occurred in a floating point division.
No response
115
Invalid value for floating point operation An invalid floating point value (e.g. NaN: not a number) was
detected in a floating point operation.
No response
116
Timeout of I2C Bus Read/Write
Eeprom
A timeout error occurred in the I2C Bus. The serial I2C EEPROM is
connected to the DSP via the I2C Bus.
m
Effect:
The Board ID and production data are stored in the I2C EEPROM.
The error may lead to an incorrect board configuration.
No response
118
Error while reading or writing the hard-
ware board data
An error has occurred while reading or writing the hardware board
data.
Pulse block
119
Drive no longer synchronous with field-
bus
The error is enabled, if the synchronization signal of the fieldbus is
more than once out of the synchronous window after a successful
synchronization.
Pulse block
121
Measured RT fieldbus cycle too large
The error is triggered when the fieldbus cycle that is measured in the
FPGA is greater than the parameterized set value fieldbus cycle.
Pulse block
122
Measured fieldbus cycle too small
The fieldbus cycle that is measured in the FPGA is smaller than the
parameterized set value fieldbus cycle
Pulse block
123
RT fieldbus jitter greater than the syn-
chronizer window
The error is triggered when the jitter of the fieldbus interrupt that is
measured in the FPGA is greater than the parameterized synchro-
nizer window.
Pulse block
124
PWM Counter 1 not synchronous with
the DSP time dial system
The error is triggered when the PWM counter of Drive 1 is no longer
synchronous with the time dial system of the DSP.
Pulse block
126
RT fieldbus run time error
The error is triggered when a error occurs in the chronological order
of data transfer in the participating modules of the fieldbus system. It
is thereby assumed that set values are received in intervals via field-
bus and transmitted to the DSP while the DSP returns DSP actual
values to the fieldbus. When run times develop during the value
transfer that are too high, a error will be indicated. A more detailed
analysis can then be carried out through the diagnostic parameters
that are provided.
Pulse block
127
Timeout fieldbus interrupt
The error is triggered when more than 3 fieldbus interrupts have
failed. The synchronization will be initiated again.
Pulse block
128
Unknown identification System FPGA
Identification of system FPGA is unknown in the DSP
Pulse block
129
System FPGA version does not fit to
DSP software
System FPGA version does not fit to DSP software
Pulse block
130
The fallback version was booted by
Bootloader 1
The fallback version was booted by Bootloader 1
Pulse block
131
The communication firmware has
booted the fallback version
The communication firmware has booted the fallback version
Pulse block
132
The firmware has booted the fallback
version
The firmware has booted the fallback version
Pulse block
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......