Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
184
3.4
time compensation is adapted according to the presently used switch frequency.
This can be different to the switch frequency at the moment of the measurement.
Better dead time compensation is reached if the used switch frequency and switch
frequency at the time of measurement are equal.
123.2
Status
This parameter shows the current status of the identification.
NOTE!
There is no way proving, if dead time measurement was executed by "Adaption ac-
cording to PWM frequency", successfully.
Value
Meaning
0
Identification inactive or completed
1
Preparation for identification
2
Identification starting
3
Switch on voltage setting
4
Voltage setting
5
Starts identification of the resistance
6
Identification of resistance or inductance
7
Error during identification of resistance or inductance
8
Identification of dead time in progress
9
10
11
12
13
Error during identification of dead time
14
Identification ready
15
Identification switched off
16
Identification cannot be switched on
17
Identification error: Set Value voltage too great.
18
Identification error: Voltage limit accessed
19
Identification error: Timeout (60 seconds) while measuring the resistance
20
Identification interrupted
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......