Summary of all Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
789
5
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
A
x
is-in
d
ep
end
e
nt
143.5
Mode 2
UINT
0
2
0
1:1
X
143.6
Position error limit 2
UDINT
0
0xFFFFFFFF 0xFFFFFFFF
1:1
X
143.7
Position error monitoring
time 2
UINT
0
0xFFFF
0xFFFF
ms
1:1
X
143.8
Field angle speed
threshold
UINT
0
100
10
%
1:1
X
143.9
Field angle counter
UINT
0
0xFFFF
0
1:1
145.1
Status
WORD
0
0xFFF
0x0
1:1
X
145.2
Mode
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
145.3
Gear slave shaft revolu-
tions
DINT
-2147483647
2147483647
1
1:1
X
145.4
Gear master shaft revo-
lutions
DINT
1
2147483647
1
1:1
X
145.5
Speed limit master shaft UDINT
0
0x7FFFFFFF 0x7FFFFFFF
Inc/
Tab
1:1
X
145.6
Synchronization veloc-
ity window
UDINT
1
2147483647
10000
Inc/ms 10000:1
X
145.7
Synchronization accel-
eration
UDINT
1
6553600
10000
Inc/
ms²
10000:1
X
X
145.8
Synchronization decel-
eration
UDINT
1
6553600
10000
Inc/
ms²
10000:1
X
X
145.9
Synchronization maxi-
mum jerk
UDINT
1
6553600
1000
Inc/
ms³
10000:1
X
X
145.10
Virtual master speed set
value
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.11
Virt. master set value
cycle time
UINT
1
128
1
ms
1:1
X
145.12
Master speed
DINT
-2147483647
2147483647
0
Inc/ms 10000:1 X
145.13
Master position revolu-
tions
UDINT
0
0xFFFFFFFF 0
Inc
1:1
145.14
Master position angle
UDINT
0
0xFFFFFFFF 0
Inc
1:1
145.15
Master speed set value
additive 1
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.16
Master speed set value
additive 2
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.18
Master angle offset
DINT
0x80000000
0x7FFFFFFF
0x0
Inc
1:1
X
146.1
Asynchronous Motor
Mode
UINT
0
0xFFFF
0
1:1
X
146.13
Flux set value
FLOAT
-1e9
1e9
1
%
1:100
X
146.14
Actual flux
FLOAT
-1e9
1e9
0
%
1:100
X
146.16
Slip preset value
DINT
0x80000000
0x7FFFFFFF
0
Inc/
Tab
1:1
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......