797
5
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
A
x
is-in
d
ep
end
e
nt
166.19
Frequency reduction
FLOAT
-1e9
1e9
0
Hz
6.28318
53 : 1
X
166.20
Additional voltage
FLOAT
-1e9
1e9
0
V
1:1
X
166.21
Frequency f0
FLOAT
0
0xFFFFFFFF 0
Hz
6.28318
53 : 1
X
166.22
Reference frequency
FLOAT
-1e9
1e9
0
Hz
6.28318
53 : 1
X
166.23
Additional frequency
FLOAT
-1e9
1e9
0
Hz
6.28318
53 : 1
X
166.24
Frequency of ramp gen-
erator
FLOAT
-1e9
1e9
0
Hz
360:1
X
166.25
Kp speed correction
controller
FLOAT
0
1e9
0
1:1
X
166.26
Tn speed correction
controller
FLOAT
0
1e9
0
ms
1:1
X
166.27
Time constant slip filter
FLOAT
0
100000
100
ms
1:1
X
167.1
Catch enable
UDINT
0
1
0
1:1
X
167.2
Catch flux estimator
gain
FLOAT
1.0
1000.00
25.00
1:1
X
167.3
Catch demagnetization
time
UINT
0
4000
0
ms
1:1
X
168.1
Status
WORD
0
0xFFFF
0
1:1
X
168.2
Mode
WORD
0
0xFFFF
0
1:1
X
X
168.3
Output
INT
-16384
16384
0
%
16384:
100
X
168.4
Upper Limit
INT
-16384
16384
16384
%
16384:
100
X
168.5
Lower Limit
INT
-16384
16384
-16384
%
16384:
100
X
168.6
Increment
INT
0
2000
100
%
100:1
X
169.1
Mode
UDINT
0
0xFFFFFFFF 0
1:1
X
X
169.2
Status
UDINT
0
0xFFFFFFFF 0
1:1
X
X
169.3
Position difference limit
UDINT
0
0xFFFFFFFF 0x00010000
Inc
1:1
X
X
169.4
Position difference time UINT
0
65535
1000
ms
1:1
X
X
169.5
Actual position differ-
ence
DINT
-2147483648
2147483647
0
Inc
1:1
X
X
169.6
Current difference limit
FLOAT
0
10000
1.0
A
1:1
X
X
169.7
Current difference time
UINT
0
65535
1000
ms
1:1
X
X
169.8
Actual current difference FLOAT
-10000
10000
0
A
1:1
X
X
171.1
Control word reluctance UINT
0
0xFFFF
0
1:1
171.3
Ld curve family
FLOAT
1e-5
1e9
1e-3
mH
1:1000
X
171.4
Lq curve family
FLOAT
1e-5
1e9
1e-3
mH
1:1000
X
171.5
Norm current for induc-
tance chart familiy
FLOAT
0.01
1e9
10
A
1:1
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......