Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
479
3
Asynchronous motor
The maximum Id current (Saturation magnetizing current
) is supplied at an
asynchronous motor. The motor flux increases with the Id current and thereby the re-
quired voltage. The field weakening controller counteracts the Udc link controller and the
maximum Id current cannot be supplied, if the required voltage exceeds the available volt-
age.
At high speeds it is possible to supply block-shaped Id current with the output of the Udc
link-ld controller. At this process the flux increases and decreases dependent of the ld
current signs.
The sign of the ld current changes, if the actual flux value (
) exceeds the limits,
which are between 100% of the flux set value and the adjustable threshold (
The block-shaped ld current is supplied above the adjustable threshold (
) - below
the threshold positive ld current is supplied, only.
3.7.4.4 Short circuit brake
Synchronous motors are able to be braked using a short circuit brake, additionally. If the
DC link voltage exceeds a set threshold, the motor phases are shorted and the current
no longer flows into the DC link. The motor is decelerated by the resulting current.
3.7.4.5 Parameter Overview of the DC link controller
Functional block:
FbUzkcontroller [114]
For Parameter 130.3, see
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Re
ad o
n
ly
St
o
ra
g
e
DS Su
pp
ort
Cy
clic W
rite
Ax
is-in
d
ep
ende
nt
114.1
DC link controller set
value
FLOAT
10
850
850
V
1:1
X
114.2
Kp DC link controller
FLOAT
0.001
256
0.01
1/V
1:1
X
114.3
Tn of DC link controller
FLOAT
0
1000
0.2
ms
1:1
X
114.5
Iq upper limit DC link ctrl FLOAT
0
10000
10000
A
1:1
X
114.6
Iq lower limit DC link ctrl FLOAT
-10000
0
-10000
A
1:1
X
114.7
Speed threshold for
block shape current
FLOAT
0
1e9
600000
Grad/s 1:1
X
114.8
Flux threshold
FLOAT
0
1
0.5
%
1:100
X
O
114.9
DC link voltage hystere-
sis
FLOAT
0
100
0
V
1:1
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......