![Baumuller b maXX BM5800 Скачать руководство пользователя страница 574](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380574.webp)
Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
574
3.8
Homing methods -9 and -10:
These methods are used to move to a mechanical stop and finally referenced to the en-
coder zero angle or zero pulse.
With Mode –9 the drive moves clockwise and with –10 counterclockwise toward the me-
chanical stop.
m
Phase 1
Identical with homing methods –7 and –8
m
Phase 2
When the mechanical stop is recognized, the torque limit
Homing torque
limit
is canceled again and referenced in the reverse direction of travel with
Homing final speed
to the encoder zero angle or zero pulse.
During homing runs to a mechanical stop, specific monitoring procedures may trigger a
error due to the mechanical blocking. This includes the position error monitoring, moni-
toring of speed difference and block monitoring.
Activating the
Mode bit 5 will prompt the controller to deactivate the three mon-
itoring procedures for the period of homing, which means from the start of homing to the
recognition of the mechanical stop after expiration of the
Homing blocking
time.
3.8.3.19 Command set home position
Besides the homing it is possible to set the reference point in the inhibited state (pulse
inhibit). By writing the command "Set reference point" to the parameter
the set
value of the reference point is taken over at the current position.
The drive acknowledges the setting of the reference point by setting the bit 2 in the pa-
rameter Homing status
. By writing the command value 0 the bit 2 in the homing
status is reset again.
However the command is possible in the inhibited state only independent of the current
operation mode of the drive.
3.8.3.20 Parameter overview
Functional block:
FbHoming [120]
CAUTION!
1
The controller cannot distinguish with homing methods –7, -8, -9 and –10 whether
the block is caused by the mechanical stop or otherwise! In the second case, the
drive is incorrectly referenced!
2
The machine may be damaged with homing methods against mechanical stops.
The user must prevent this through a sufficiently low setting of the homing speed
(
) and the maximum drive torque during homing (
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......