Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
224
3.4
3.4.12.3 Description of the Parameter
124.1
Configuration Mode
Configuration of the measuring encoder
124.24
Encoder 2 trigger digital
input TP2 neg. edge
angle
UDINT
0
0xFFFFFFFF 0
1:1
X
X
124.25
Encoder 2 trigger zero
pulse pos. edge revolu-
tions
UDINT
0
0xFFFFFFFF 0
1:1
X
X
124.26
Encoder 2 trigger zero
pulse pos. edge angle
UDINT
0
0xFFFFFFFF 0
1:1
X
X
124.27
Encoder 2 trigger zero
pulse neg. edge revolu-
tions
UDINT
0
0xFFFFFFFF 0
1:1
X
X
124.28
Encoder 2 trigger zero
pulse neg. edge angle
UDINT
0
0xFFFFFFFF 0
1:1
X
X
124.30
DS402 mode
UDINT
0
0xFFFFFFFF 0x00100100
1:1
X
124.31
DS402 touch probe 1
pos. value
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
124.32
DS402 touch probe 1
neg. value
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
124.33
DS402 touch probe 2
pos. value
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
124.34
DS402 touch probe 2
neg. value
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
NOTE!
All
measurements are inactive during the change of the configuration!
Bit
Meaning
Encoder 1
0…2 Measurement "Encoder 1 with Trigger digital input TP1"
0
Activation channel measurement positive edge
(Enc1TrDi1PosValRev/Enc1TrDi1PosValPhi)
0: switch off
1: switch on
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......