![Baumuller b maXX BM5800 Скачать руководство пользователя страница 333](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380333.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
333
3
Pulses are inhibited (drive is without torque)
If the drive is suddenly without torque due to a pulse inhibit (response to QUICK
STOP/SHUT-DOWN/INHIBIT/drive error), the brake could be applied immediately or
when the speed threshold (see above) is reached. With a suspended load, it is recom-
mended that the brake be allowed to be applied immediately in this case (
Bit 2 = 0) as the drive could be accelerated by the externally acting torque, with the result
that the speed threshold is not reached and the brake is not applied.
Figure 84:
Braking procedure in the "Automatic" brake control mode
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......