Management
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
314
3.5
108.15
DISABLE OPERATION reaction code
This parameter is only relevant for axis units.
See also
This parameter defines the response of the drive during the transition from the OPERA-
TION ENABLED to the SWITCHED ON state in the state machine for the device control-
ler.
For correct functioning of the braking procedures on the Quick Stop or Ramp-down
ramps, the speed controller must be adequately configured.
108.16
Status internal limits
This parameter is only relevant for axis units.
Status bit string for internal limits
Value
Meaning
0
Inhibit drive immediately
1
Return to ramp-down ramp
2
Return to Quick Stop ramp
3
Return to current limit
NOTICE!
Do not use return to current limit during U/f operation
Bit #
Meaning
0
1: Current/torque limited
1
1: Speed set value limited at speed controller input
2
1: Speed limited during set value generation
3
Reserved
4
1: Negative HW limit switch is set (even if not limited)
5
1: Positive HW limit switch is set (even if not limited)
6
1: Negative SW limit switch is set (target position was outside, now limited)
7
1: Positive SW limit switch is set (target position was outside, now limited)
8…31
Reserved
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......