![Baumuller b maXX BM5800 Скачать руководство пользователя страница 696](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380696.webp)
Diagnosis
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
696
3.10
3.10.3.2 Description of the Parameter
104.1
Command
This parameter can be used to switch the FFT analyzer function on or off.
104.2
Status
This parameter shows the current status of the module.
104.14
Frequency for sinus
generator
FLOAT
0
8000
0
Hz
1:1
X
X
104.15
Signal out
FLOAT
-1e+9
1e+9
0
1:1
X
X
104.16
Input signal 1
FLOAT
-1e+9
1e+9
0.00
1:1
X
X
104.17
Input signal 2
FLOAT
-1e+9
1e+9
0.00
1:1
X
X
104.18
Actual average
DINT
0
20000
0
1:1
X
X
104.19
Max. frequency
FLOAT
0.00 8000
2000
Hz
1:1
X
X
104.20
Frequency resolution
FLOAT
0.00 62.5
9.765625e-01
Hz
1:1
X
X
104.21
FFT data
FLOAT
0
0
0
1:1
X
X
104.22
Prbs register length
UINT
0
19
19
1:1
104.23
Prbs register clock
UINT
1
0xFFFF
1
1:1
FFT Command Meaning
0
Stop
1
Run
Status
Meaning
0
Idle
1
Initialization Memory
3
Initialization Window Function
5
Start Average
8
Get Signal Initialization
9
Get Signal
11,12
Windowing Signal Ch1, Ch2
13,15
FFT Ch1, Ch2
17
Standardization
20,22
Auto, Cross Spectrum
24, 25, 26 ÜTF, PHI, Coherence Calculation
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......