Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
100
3.4
107.19
Pole pairs
Number of pole pairs in the motor. If the motor has no electronic identification plate, the
number of pole pairs must be entered.
107.20
Ke factor
Display motor-voltage constant at the "cold" motor in V/1000 rpm. Motor EMF referring to
1000 rpm.
At the ASM the Ke factor refers to the "warm" motor (operating temperature). However,
the difference between the "cold" and the "warm" motor usually is negligible. At the SM
the Ke factor refers to the "cold" motor whereas the difference between "cold" and the
"warm" motor is about 5% in average.
If the motor has no electronic identification plate, the Ke factor must be entered. If no val-
ue for the Ke factor is available, the following procedure is possible:
m
Define the speed set value according to the nominal speed of the motor
m
Enable the drive and operate it no-load
m
By altering the Ke factor, bring the Iq controller output to approx. 0%
(When changing the Ke factor
107.20
in the enabled state the used value in the con-
troller is smoothed to reduce the interferences in the controller. The temporal change
of the smoothing Ke factor can be monitored in the parameter
(Ke-factor in
V/N
nom
.)
Refer to EMF pre-control (
on page 504) of the exact correlation between the
speed actual value and the EMF pre-control.
107.21
Max. current
Peak current of the motor. The value displayed is read from motors with an electronic
identification plate and is used for the injection procedure.
107.22
Peak torque
Peak torque of the motor. The value displayed is read from motors with an electronic iden-
tification plate and is for information only.
NOTE!
At the encoderless operation of the asynchronous motors the parameter
107.20
is not
important and has an informative meaning, only.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......