3
120.11
Homing blocking time
Adjustable blocking period for reference run modes to the mechanical stop only.
The parameter indicates the period of time after which the mechanical stop is recognized
when the drive is blocked. The conditions for blocking are "Drive at current limit" and, at
the same time, the speed zero message.
120.12
Homing torque current limit
Limiting the torque for reference run modes to the mechanical stop only.
The limiting begins with the start of the homing to a mechanical stop and will be canceled
when the mechanical stop is recognized.
The homing modes to the mechanical adjustable stop were implemented mainly at the
SM without field weakening. The limitation of the torque is made by the limitation of the
"Max. drive current actual value"
. This means that the field current is assumed
zero so that the limit of the total current = torque current limit. When starting the homing
to the mechanical adjustable stop the total current limit is reported (
bit 4).
Standardization:
100%
=
Max. torque current
120.13
Output speed set value
Speed start value (Position Delta) of the reference run module.
120.14
Output acceleration set value
Acceleration start value of the reference run module.
120.15
Encoder angle at reference switch
Encoder angle plus adjusted offset at the reference switch in 32 Bit increments per turn.
To check whether the zero angle of the encoder is in the range of switch tolerances of the
reference switch.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......