Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
526
3.8
Bit 6:
Error - Command aborted at positive stop
The error is generated if the command is aborted at following states:
– the N=0 message is generated and
– the clamping moment is reached,
– but the message "Positive stop reached" was not generated by the controller yet
Status bit 10 = 0).
Bit 8:
Copy of the standstill message (
) of the motor encoder, the bit is updated at ac-
tive command only.
Bit 9:
The bit is set if the torque actual value has reached the clamping torque. The bit is up-
dated independently on the n=0 message as far as the command is active.
Bit 10:
Message "Positive stop reached" is set if the n=0 message and the message "Clamp-
ing torque reached" are present constantly during the Blocking time (
).
121.23
Mode positive stop drive
Note:
Bit 2:
If the bit is set, the parameter
Homing torque limit [%] related to the maxi-
mum available torque current
is not evaluated during the command.
121.24
Positive stop position
When reaching the positive stop (
bit 10 = 1 "Positive stop reached") the con-
troller stores the current position actual value (
) in this parameter.
This value is the base for positive stop monitoring via monitoring window.
Bit
Meaning
0 -1
Monitoring positive stop
00: no monitoring
01: via monitoring window positive stop
10: via N=0 message
11: Reserved
2
0: torque reduction via
active
1: torque reduction via
disabled
15 ... 3
Reserved
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......