![Baumuller b maXX BM5800 Скачать руководство пользователя страница 231](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380231.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
231
3
Attention:
The status bits 12…17 and 20…21 remain set with continuous triggering of the corre-
sponding channel (P124.1) after the first measurement. For signaling, the additional use
of P124.4 is recommended where new measured values of the channels are signaled
through toggle bits.
124.4
Status 2
Extended status of the measuring encoder.
Toggle bits to signal new measurements with continuous triggering (refer to
21…20
Status of measured value storage Measurement Channel "Encoder 1 with
Trigger digital input TP1":
00: No measured value stored yet
01: Measured value positive edge stored
10: Measured value negative edge stored
11: Measured value po negative edge stored
23…22
Status of measured value storage Measurement Channel "Encoder 1 with
Trigger digital input TP2":
00: No measured value stored yet
01: Measured value positive edge stored
10: Measured value negative edge stored
11: Measured value po negative edge stored
25…24
Status of measured value storage channel "Encoder 1 with Zero Pulse":
00: No measured value stored yet
01: Measured value positive edge stored
10: Measured value negative edge stored
11: Measured value po negative edge stored
27…26
Status of measured value storage Measurement Channel "Encoder 2 with
Trigger digital input TP1":
00: No measured value stored yet
01: Measured value positive edge stored
10: Measured value negative edge stored
11: Measured value po negative edge stored
29…28
Status of measured value storage Measurement Channel "Encoder 2 with
Trigger digital input TP2":
00: No measured value stored yet
01: Measured value positive edge stored
10: Measured value negative edge stored
11: Measured value po negative edge stored
31…30
Status of measured value storage channel "Encoder 2 with Zero Pulse":
00: No measured value stored yet
01: Measured value positive edge stored
10: Measured value negative edge stored
11: Measured value po negative edge stored
Bit
Meaning
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...