14.16
Error count incremental encoder
Display of how often an incremental encoder error has been detected.
14.17
Encoder error mask
Bit field for selecting the active encoder monitors.
When Bit 0 = 1 the encoder monitoring is activated. With Bits 1 to 6 it must be set which
of the several monitoring functions operate.
When Bit 0 = 0, the encoder monitoring is disabled completely.
14.19
Cycle time variance calculation
Cycle time of the variance calculation in ms.
14.20
Status variance calculation
Internal status of the variance calculation.
14.21
Position monitoring error threshold
Error threshold for position actual value monitoring, see
bit 7. Mechanical angle
in degrees.
Bit #
Meaning
0
0: Encoder monitoring switched off
1: Encoder monitoring switched on
1
Monitoring of maximum signal amplitude active
2
Monitoring of minimum signal amplitude active
3
Monitoring of sectors active
4
Monitoring of the square-wave incremental encoder active
5
Monitoring of the position initialization active
6
Variance monitoring active
7
Monitoring of the position actual value.
This monitoring must not be enabled at length measuring devices (linear
encoders).
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......