![Baumuller b maXX BM5800 Скачать руководство пользователя страница 590](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380590.webp)
Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
590
3.8
deleted. bit 12 „In position“ in
Spindle positioning status is a copy of bit 10 "Set
value reached" in
Status word 1.
Operating sequence of a spindle positioning with a subsequent sequential
positioning
Figure 164:
Spindle positioning with sequential positioning
Instant of time 1: Switching to operating mode spindle positioning; deceleration to spin-
dle positioning speed.
Instant of time 2: Position setpoint has reached active target position
.
Instant of time 3: Position actual value is in positioning window and positioning window
time is up
Controller sets "Setpoint reached".
Instant of time 4: „Start sequential positioning“ is set.
Instant of time 5: Controller has recognized a start command, resets „Setpoint reached“,
sets the „Start-Command-Acknowledge“ and begins with sequential positioning.
Instant of time 6: „Start sequential positioning“ is deleted.
Instant of time 7: Controller deletes „Start-Command-Acknowledge“.
Instant of time 8: Position setpoint has reached active target position.
Instant of time 9: The position actual value is in positioning window and positioning win-
dow time is up
Controller sets "Setpoint reached".
NOTE!
Bit 11 of the control word is only used for the sequential positioning. The first posi-
tioning after switching to operating mode spindle positioning is always executed im-
mediately independent of the status of bit 11!
t
n
1
2 3
4 5 67
8 9
Spindle
positioning speed
Status word Bit 12
„Start-Command-
Acknowledge“
Status word Bit 10
„Setpoint reached“
Control word Bit 11
„Start sequential
positioning“
Switched to
operating mode -6 spindle positioning
Slow down with spindle acceleration bipolar
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......