![Baumuller b maXX BM5800 Скачать руководство пользователя страница 730](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380730.webp)
Error detection
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
730
4.3
4.3
Error detection
The BM5800 has the following options for component placement:
m
No LEDs
m
2 LEDs
m
8 LEDs
4.3.1
LED assignment wit 8 LEDs (2 columns)
Column LED
Color / flash code
Meaning
Axis
1
H11
green
orange
green blinking
Power on and pulse enable at any
axis
Power on
Download active
1 to 7
1
H12
red permanent lighting
red blinking slow
red blinking fast
Error
Warning
Torque limit
1
1
H13
red permanent lighting
red blinking slow
red blinking fast
Error
Warning
Torque limit
2
1
H14
red permanent lighting
red blinking slow
red blinking fast
Error
Warning
Torque limit
3
2
H21
red permanent lighting
red blinking slow
red blinking fast
Error
Warning
Torque limit
4
2
H22
red permanent lighting
red blinking slow
red blinking fast
Error
Warning
Torque limit
5
2
H23
red permanent lighting
red blinking slow
red blinking fast
Error
Warning
Torque limit
6
2
H24
red permanent lighting
red blinking slow
red blinking fast
Error
Warning
Torque limit
7
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......