3.5.2.9 Data Set Commands and Possible Error Messages
m
Reset the Data Set Management System
This command results in a reset of the message list and the status word of the Data Set
Management System.
n
Possible error messages:
None
m
Write all parameters to Flash memory
This data set command saves all the parameters in the created data sets from RAM to
Flash.
m
Load parameters from Flash
This command reads all the parameters from Flash into the RAM of the device. This com-
mand is only possible when the device is locked.
During the copying procedure, any changeover of the data sets is inhibited.
Possible error messages:
n
Device is not inhibited
n
Value less than minimum value
n
Value greater than maximum value
n
Parameter is read-only
n
Due to operating state, parameter cannot be changed
n
Parameter value is invalid
n
Check yielded faulty checksum
m
Delete parameters in Flash
This data set command deletes the parameters saved in Flash.
Possible error messages:
n
Error writing to Flash
m
Set standard values for all savable parameters
All savable parameters of the device are set to their standard values. This command is
only possible when the device is locked.
m
Set standard values for axis specific parameters of an axis
All savable, axis specific parameters (so not for all axis) are set to their standard values.
This command is only possible when the device is locked.
m
Create Data Set <n>
When a device is delivered, initially only a single data set (Data Set 1) is activated. The
user cannot switch to other data sets, therefore. Only after the user has created a further
data set (2 to 7) using this command will the device allow switching to this data set. This
measure is intended to guarantee that the user cannot switch unintentionally to an as yet
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......