Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
435
3
18.71
Speed set value positive limit
The set value at the speed controller input is limited to this value in the positive range. If
limitation is active, Bit 1 is set in
status internal limits.
18.72
Speed set value negative limit
The set value at the speed controller input is limited to this value in the negative range. If
limitation is active, Bit 1 is set in
status internal limits.
18.73
x3 acceleration actual value
Effective acceleration actual value in degrees/s
2
.
18.74
x3 acceleration time constant
Time constant of the PT
1
filter to smooth the x3 acceleration actual value (
18.75
Speed controller output total
Speed controller output (or the entire acceleration set value) from the speed controller in-
cluding the acceleration feedforward term and an additional feedforward (friction compen-
sation, torque coupling etc.) in degrees/s.
18.76
Position actual angle for fieldbus
This parameter displays the angle of the actual position value in a 32 bit resolution and is
updated in the fieldbus cycle.
This parameter corresponds to
; however is latched in the controller at the fitting
transfer time of the actual position value. Therefore, it is primarily intended to be an actual
fieldbus value, for the fieldbus especially if an own position error monitoring shall be cal-
culated on the control.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......