![Baumuller b maXX BM5800 Скачать руководство пользователя страница 704](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380704.webp)
Monitoring
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
704
3.11
3.11.2 Position Error monitoring
The position error is the difference between the position set value and the actual position.
It can be monitored statically or dynamically.
The dynamic position error limit will become effective as soon as a new position set value
is available for each sampling time of the position controller.
The static position error limit becomes effective when the position controller either does
not receive a new position set value or it continues to receive the same position set value
repeatedly.
Two separate limits (thresholds) are available for position error monitoring. The following
property settings may be entered for each limit:
m
Size of the window (position error limit)
m
Response time (position error time)
m
Type of monitoring - static, dynamic or both (see Mode 1
and Mode 2
Two bits are assigned to each threshold in the Parameter
Status. If the actual
position error exceeds one of the two thresholds, the bit "Position Error Limit Exceeded"
will be set in the
Status. If the position error remains longer than the position
error time that was entered, another bit is set in the Status and the error
207 Position error limit 1 exceeded or
208 Position error limit 2 exceeded
will be reported.
If the position error falls below the threshold setting, the status bit "Position error limit ex-
ceeded" will be deleted again.
The cycle of the position error monitoring is 1 ms.
3.11.2.1 Parameter overview
Functional block:
FbMonitoring [143]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read o
n
ly
St
o
ra
g
e
DS Supp
ort
Cyclic W
rite
Axis-in
d
ep
end
e
nt
143.1
Status
WORD
0
0xFFFF
0
1:1
X
143.2
Mode 1
UINT
0
2
0
1:1
X
143.3
Position error limit 1
UDINT
0
0xFFFFFFFF 0xFFFFFFFF
1:1
X
143.4
Position error monitoring
time 1
UINT
0
0xFFFF
0xFFFF
ms
1:1
X
143.5
Mode 2
UINT
0
2
0
1:1
X
143.6
Position error limit 2
UDINT
0
0xFFFFFFFF 0xFFFFFFFF
1:1
X
143.7
Position error monitoring
time 2
UINT
0
0xFFFF
0xFFFF
ms
1:1
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......