3.8
3.8.3.10 Homing Methods 3 and 4 (pos. zero point changeover switch)
Homing occurs in the direction of the positive zero point changeover switch, which means
the switch may be anywhere in the traversing range and is continuously active from the
switch point in positive direction. The initial direction of travel depends on the switching
mode and applied method.
The home position is the first zero pulse on the left or right of the switch.
Figure 154:
Homing method 3 and 4