Monitoring
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
712
3.11
Figure 185:
Current derating at changed operating conditions
For the following operating conditions correction factors are used during the current der-
ating at changed operating conditions:
m
Control cabinet temperature of device (ambient temperature or surface tempera-
ture): Required temperature can be entered in
m
Installation altitude: Required installation altitude can be entered in
m
Voltage supply (mains voltage/DC link voltage): Required mains voltage or DC link
voltage can be entered in
or
m
Current derating dependent of the output frequency
This is described in the chapter "Correction factors at changed operating conditions" and
"Electrical data" in the operating manual.
Initialization I
2
t sub-model
The I
2
t-sub-model is set or initialized to the following value, if the heatsink temperature
exceeds 45 °C during the operating enable.
Protective function current limit
I
2
t-sub-model:
This model was implemented for components of the device, whose thermal load isn't de-
pendent of the switching frequency. The input value is standardized using the actual val-
ue of the PU-I
2
t max. continuous current
.
1
fs
1
U
1
H
1
T
5000_0299_rev01_int.cdr
Max. device
control cabine temperature,
175.3
Max. device
altitude,
175.4
Power unit
nominal current,
6.26
Power unit
Nominal current
2 kHz,
129.12
PU I2t max. continuous current actual value, 175.8
PU max. continuous current actual value, 175.7
PWM
frequency,
130.15
Max. device
mains voltage, 175.5
dc link volrage, 175.6
Output frequency
filtered,
47.49
100°C
act
45°C
–
40°C
-----------------------------------------------------
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......