3.5
The bits labeled X are not defined.
Bit 3: Error
The controller sets this bit as soon as an error (Parameter 100.2 > 0) which triggers an
error reaction from the drive appears. The bit remains set during the error reaction and in
the error state, and is only cleared when the error is successfully reset. The error LED
lights as soon as this bit is set.
Bit 4: Main supply voltage / DC link voltage present
Mono unit with its own power supply:
The bit is set when the main supply voltage is present on the power unit and the DC link
is loaded. It is cleared if the main supply fails. This bit is always updated independently to
the device state.
Bit 5: Quick Stop or request for Quick Stop active
The bit is active low and is cleared as soon as a Quick Stop response is initiated via the
"Quick Stop" control word command. When the "Ready to Switch On" state is reached,
the bit is set. If "Remain in Quick Stop" is selected as the behavior for the Quick Stop re-
sponse (Parameter
QuickstopCode (QUICK STOP reaction code) Values 5 to
8), this bit remains cleared for as long as the drive is in Quick Stop. The bit is set once
more as soon as the drive is enabled again or the "Ready to Switch On" state is reached
as a result of a command.
Bit 7: Warning
This bit indicates when a warning or an error which does not result in any error reaction
is present in the controller. This state can be recognized externally by the flashing of the
error LED.
Bit 8: Status of ramp function generator is Stop
m
Speed control (Operating mode -3) and speed setting (Operating mode 2):
This bit indicates that the ramp function generator has been stopped and its output is
therefore frozen.
m
Coupled operation (operation mode -12)
1: A reloaded curve is ready to be activated.
0: A reloaded curve was activated and there is no curve available anymore
QUICK STOP ACTIVE
0
0
0
1
1
1
ERROR RESPONSE ACTIVE 0
X
1
1
1
1
ERROR
0
1
1
0
0
0
a)
This bit is active low
Bit in the Status Word
Device Controller State
Bit 6
Switch-on
Inhibit
Bit 5
Quick
Stop
a)
Bit 3
Error
Bit 2
Operation
Enabled
Bit 1
Switched
on
Bit 0
Ready to
switch on
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......