3.6.6
Motor potentiometer
Changes of the speed set value can be forced by the motor potentiometer depending on
two control bits (Motor potent and Motor potentiometer-). The motor potentiom-
eter writes directly on the ramp function parameter
Input 16 bit.
The motor potentiometer is activated via the control parameter
Mode.
The motor potentiometer parameter
Increment indicates the amount of the in-
crease/decrease of the motor potentiometer output
Parameter
bit 4 sets whether the motor potentiometer function operates edge
sensitive or level sensitive:
m
edge sensitive
At increasing edge of
bit 2 Motor
Increment is added or subtracted once.
m
level sensitive
At increasing edge of
bit 2 Motor
Increment is added or subtracted every 32 ms.
The output of the Motor potentiometer is limited by an upper and a lower limit.
The output of the Motor potentiometer is set to 0 or is synchronized with the ramp function
generator parameter
Input 16 bit depending on parameterization of
Mode bit 3 at activation of the Motor potentiometer.
The output of the motor potentiometer
is checked for limits and if necessary ad-
justed in case of Motor potenti/- is activated. If the upper limit is changed so that
the output of the Motor potentiometer is greater than this limit, the output is adjusted
downwards with an activated Motor potent function. The modification occurs di-
rectly without transient.
3.6.6.1 Parameter Overview
Function block:
FbMotorpotentiometer[168]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Re
ad o
n
ly
St
o
ra
g
e
DS Su
pp
ort
Cy
clic W
rite
Ax
is-in
d
epe
nde
nt
168.1
Status
WORD
0
0xFFFF
0
1:1
X
168.2
Mode
WORD
0
0xFFFF
0
1:1
X
X
168.3
Output
INT
-16384
16384
0
%
16384:
100
X
168.4
Upper Limit
INT
-16384
16384
16384
%
16384:
100
X
168.5
Lower Limit
INT
-16384
16384
-16384
%
16384:
100
X
168.6
Increment
INT
0
2000
100
%
100:1
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......