Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
624
3.8
3.8.8.2 Parameter overview Notch Position Search
3.8.8.3 Description of the Notch Position Search parameters
127.1
Init.Pos.Detection method
Parameter to set the method for the terminal position search:
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read only
St
o
ra
g
e
DS Sup
port
Cyclic W
rite
Axis-i
ndep
e
nd
ent
127.1
Init.Pos.Detection
Method
INT
0
3
0
1:1
X
127.4
Max. current notch posi-
tion
FLOAT
0
20000
0
A
1:1
X
127.5
Current rise
FLOAT
0.001
100
1
A/s
1:1
X
127.6
Current drop
FLOAT
0.001
100
5
A/s
1:1
X
127.7
Duration constant cur-
rent
FLOAT
0
10
1
s
1:1
X
127.8
Notch position electrical UINT
0
0xFFFF
0
Grad
1:1
X
127.9
Maximum angle
UINT
1
0xFFFF
0x005b
Inc
1:1
X
127.10
Angle rising
UINT
1
0xFFFF
1
Inc/ms 1:1
X
127.11
Error limit mech. delta
angle
UINT
1
0xFFFF
0x5B0
Inc
1:1
X
127.12
Averaging zero speed
detection
UINT
1
1024
100
1:1
X
127.13
Actual value mech. delta
angle
INT
-32767
32767
0
Inc
1:1
X
Value
Meaning
0
Method 0: Constant current feed angle and turning axis
1
Method 1: Nearly constant position of motor axis and variable current feed
angle
2
Method 2: Injection procedure
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......