Error messages and troubleshooting
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
733
4
133
The FPGA has booted the fallback ver-
sion
The FPGA has booted the fallback version
Pulse block
134
System FPGA and option module type
are not compatible
The system FPGA is incompatible with the connected option mod-
ule. An error occurs during the booting procedure.
n
Remedy
Load the appropriate system FPGA
No response
135
Error while programming to flash
Error while programming to flash
No response
137
Time dial computation time overrun
It is being monitored whether the time dials exceed the run time of
MAX_ZS_TIME_LIMIT_IN_TICK = 60 µs too frequently.
Monitoring in remaining time, threshold: per second = 1000*16 ZS,
10% of that: 1600 overruns per second
Pulse block
138
Cycle2 duration too long
Cycle2 duration more than 1% too long in relation to one second.
The CPU is overloaded, computation too great.
Pulse block
139
Drive not synchronous with RT fieldbus
(Warning)
This warning message is issued when the synchronization of the
drive with the fieldbus is activated (Parameter
not yet occurred (Parameter
). The message occurs regard-
less of the fieldbus status (operational / not operational) and will be
deleted when the drive is synchronous.
Required for better error diagnosis because the drive cannot be
enabled if synchronicity is required but has not been achieved.
No response
140
General firmware error, e.g. switch
General firmware error, e.g. switch
Pulse block
141
Operating system error
Error in context with the operating system
Pulse block
142
Method not implemented
Method not implemented
Pulse block
144
invalid file type
invalid file type
No response
145
File already open
File already open
No response
146
Maximum size of file reached (writing
reading)
Maximum size of file reached (writing reading)
No response
147
File not opened
File not opened
No response
148
File not opened for this access (Read
Write access)
File not opened for this access (Read Write access)
No response
149
Indicated ID wrong
Indicated ID wrong
No response
150
Indicated index does not exist (too
large)
Indicated index does not exist (too large)
No response
151
Parameter element cannot be written
Parameter element cannot be written
No response
152
External access not permitted
External access not permitted
No response
153
Value less minimum value
Value less minimum value
No response
154
Value greater maximum value
Value greater maximum value
No response
155
Value error
Value error
No response
156
Value cannot be changed due to the
operating condition
Value cannot be changed due to the operating condition
No response
157
wrong axis index
wrong axis index
No response
158
Format information wrong
Format information wrong
No response
159
Error while reading system data
Error while reading system data from flash
No response
160
No log file available
168
No write permission for the actual
access level
Parameter cannot be changed due to the access protection. No
write permission for the actual access level.
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......