Operating Modes
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
520
3.8
When the position resolution is a squaring, then the maximum revolution must be in-
creased by one.
Maximum position value = (Maximum revolution * position resolution) - 1
121.11
Speed limit
Bipolar limit to limit the output speed of the positioning operating modes.
Additionally the
Maximum mechanical speed of the motor for determination of
the effective speed limit in the below-mentioned operating modes is used for the protec-
tion of the motor and the mechanical setup. The lesser value of the parameter
and
is effective.
The maximum possible speed on the load side results from
divided by the ac-
tive gear ratio
. As soon as the operating modes are activated the calculation of
the limit is started. The limit is
not
adjusted if
Gear ratio is changed in the status
„operation enabled“!
The lower value of
and
/
is activated for limitation.
If the value 0 rpm is entered in
, the value is ignored at the determination of the
speed limit, i.e.
is effective.
Reference run (Operating mode 6):
If the set
Homing speed exceeds the effective speed limit (
and
respectively), the speed will be reduced to the value of the limit and bit 6 is set
in the
Position target specification (Operating mode 1) and manual operation (Operating
mode 5):
If the set
Speed or
Jogging speed multiplied with the
Feed
rate override exceeds the effective speed limit (
and
respectively),
the speed will be reduced to the value of the limit and bit 6 is set in the corresponding
operating mode status (
or
Position control (Operating mode -4):
The input position values including offset parameters (
) are moni-
tored for overspeed. If the resulting set value speed exceeds the effective speed limit
(
and
respectively), the speed will be reduced to the value of the lim-
it, the error 910 "Overspeed detected at the set value input" will be triggered and bit 6 will
be set in the
Status.
The following applies especially to the input set values
Target position and
Target offset:
NOTE!
For MotionControl applications, the position resolution is permanently set to 65536
Inc/revolution!
The result is a maximum position value of FFFFFFFF
hex
.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......