Cycle times of the software modules
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
48
3.1
*) this means the cycle of the setpoint generation, the cycle of the monitorings,
the cycle of the management and the cycle of the other functions of the preset
operation mode
Analogous outputs
Adjustable values: 62.5 µs, RT0-cycle time or RT1-cycle
time
Digital inputs
1 ms
Digital outputs
Remaining time
Configurable status word 1 ms
Oscilloscope function
Adjustable from 62.5 µs to 100 s.
Operation mode
Task
-12
Coupled operation
Fieldbus
-7
Autotuning
Remaining time (manage-
ment)
-6
Spindle positioning
RT1
-5
Synchronous operation with virtual master axis RT1
Synchronous operation with real master axis
RT0 (Setpoint), RT1 (Man-
agement)
-4
Position control
Fieldbus
-3
Speed control
RT1 (default setting) or
fieldbus
-2
Current control
RT0
-1
Notch position search
RT1
1
Target position setting
RT1
2
Speed setting
RT1 (default setting) or
fieldbus
5
Manual drive operation
RT1
6
Reference run operation
RT1
Software module
Cycle time
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......