Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
375
3
132.2
Status
Status of the set value generator
132.3
Output
Output of the set value generator
The output value is written to the preset target parameter 132.4.
132.4
Target number output
Selection of the target parameter to which the set value generator writes. All cyclic writ-
able parameters are allowed.
132.10
Set value 1
Set value in Time zone 1 of the set value generator.
When the set value generator is started, a check is made to make sure that the set value
lies within the range of values in the target parameter and if necessary an error message
is issued.
132.11
Duration zone 1
Duration of Time zone 1 for the set value generator in ms. The associated set value is
applied to the output of the generator for this duration.
Bit #
Meaning
1…0
00: Set value generation is switched off
01: Set value generation is being initialized
10: Set value generation is suspended, awaiting (renewed) enabling of the
drive
11: Set value generation is switched on
3…2
Reserved
4
0: No error
1: Error
31…5
Reserved
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......