Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
671
3
Hints to achieve best possible performance
1
PWM switching frequencies recommended: 2 kHz and 4 kHz
2
The auto-tuning of the current regulator and the ID of the magnetizing curve (Lh-char-
acteristic) must be executed to measure optimal parameters for motor model and for
compensation of the power unit nonlinearity.
3
Parameter Dead time compensation
may be decreased in small steps of 1%
in the range 100% - 90% to reduce the speed ripple and to improve starting perfor-
mance.
4
Parameter Flux estimator gain
may be increased in range 250 - 750 to
achieve smooth operation at low speed and to improve starting performance.
5
Parameter Minimum speed threshold OL
can be decreased, if the operation
with frequency bellow 1 Hz is required or if smooth starting is needed. But the reliability
and repeatability of starting may be affected.
6
Parameter Minimum speed delay OL
may be decreased to lock the flux esti-
mation and prevent the loss of motor control at stand still.
If the drive does not follow a deceleration ramp, e.g. drive in current limit, the parameter
may be increased to allow speed control down to zero.
7
Auto-tuning of the speed regulator (closed loop analysis) is not possible at open loop
control. The Ks Scaling factor
must be calculated accordingly to the following
equitation:
8
Adjust the parameter Slip frequency warm
which corresponds to rated motor
slip at rated load to decrease speed estimation error.
9
At enabling of the regulator the field current follows a ramp to build the flux. With pa-
rameter Magnetization time
the length of the ramp can be set.
Motor parameters needed for commissioning
Nominal voltage
Nominal current
Nominal speed
Nominal frequency
Pole pairs
Magnetic current
Slip frequency warm
K
s
K
t
J
-----
360
o
2
-----------
=
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......