3.4
131.20
Division ratio fieldbus task
The set value generator for the cyclical set values (=
fieldbus task cycle) is exe-
cuted in every fieldbus cycle (
). A quicker cycle than the fieldbus cycle can be
set by the division ratio.
Division ratio =
1: Cyclical set value generator is activated once per fieldbus cycle
2: Cyclical set value generator is activated twice per fieldbus cycle
4: Cyclical set value generator is activated four times per fieldbus cycle
etc.
The resulting
fieldbus task cycle may not fall below the
RTO cycle time
and should at least be 250 µs.
Example:
Fieldbus cycle time = 2 ms; division ratio = 8;
2 ms / 8 = 250 µs.
A call up ratio greater than 8 would no longer be admissible anymore.
The following operating modes are considered as cyclical set values:
m
= -4; position control;
target position and
target angle
m
master axis position revolutions and
master axis position angle
131.21
Configuration profile 1
This parameter configures the used drive profile in the fieldbus slave.
The definition of the parameter depends on the fieldbus slave type. The description is to
be found in the corresponding technical documentation.
The controller must be rebooted after changing a parameter.
For other specific settings corresponding to the fieldbus, see parameter
Slave
settings.
NOTE!
A parameter change is permitted at a inhibited state and in the fieldbus state INIT
(
slave info bit 0 and 1), only.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......