Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
241
3
The functional diagram is described below:
Figure 70:
PID controller functional diagram
3.4.13.1 Parameter overview
Functional block:
FbPidCtrl[150]
+
-
+
0x0000
0x0000
0x0000
0x0000
5000_0185_rev01_int.cdr
PID controller
upper limit
P150.11/27
Set value
PID controller
P150.13/29
PID controller
Integral term
P150.16/32
Actual value
PID controller
P150.14/30
PID controller
output
P150.15/31
Target
Pxxxx
I controller
D controller
P controller
PID controller
activated
PID controller
deactivated
P-gain
P150.7/23
I-gain
P/Tn = P150.7/23 /
P150.8/24
D-gain:
P*Tn = P150.7/23 *
P150.9/25
PID controller
lower limit
P150.12/28
Pt1 time constant
PID controller
P150.10/26
Mode PID controller
P150.1/17, Bit 4
Source number set value PID controller
P150.4/20 = 0
Target number
P150.6/22 = 0
Set value
Pxxxx
Actual value
Pxxxx
P150.4/20 = Parameter number
P150.6/22 = Target number
Mode PID controller
P150.1, Bit 5
PID controller mode
P150.1/17( Bit 2, 1, 0 ) = 0
PID controller deactivated
= 1 and current controller active
PID controller activated
= 2 and speed controller active
PID controller activated
= 3 and position controller active
PID controller activated
= 4
PID active always
PID controller deactivated:
PID controller output (P150.15/31),PID controller integral term (P150.16/32) will be set to 0
Mode PID controller
P150.1/17, Bit 6
P150.5/21 = Parameter number
PID controller
upper limit
P150.11/27
PID controller
lower limit
P150.12/28
Source number
actual value PID controller
P150.5/21 = 0
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
only
St
o
ra
g
e
DS Sup
port
Cyclic W
rite
Axis-
inde
pend
ent
150.1
Mode PID controller 1
WORD
0
0xFFFF
0
1:1
X
X
150.2
Status PID controller 1
WORD
0
0xFFFF
0
1:1
X
X
150.3
Axis index PID controller
1
UINT
0
1
0
1:1
X
150.4
Source number set
value PID controller 1
UDINT
0
0xFFFFFFFF 0
1:1
X
X
150.5
Source number actual
value PID controller 1
UDINT
0
0xFFFFFFFF 0
1:1
X
X
150.6
Target number output
PID controller 1
UDINT
0
0xFFFFFFFF 0
1:1
X
X
150.7
Kp PID controller 1
FLOAT
0
100000
1
1:1
X
O
X
150.8
Tn PID controller 1
FLOAT
0.000001
100000
0.01
s
1:1
X
X
150.9
Td PID controller 1
FLOAT
0
100000
0
s
1:1
X
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......